Inquire now to find the best fit for your Precision Cooling needs

AM SERIES

• 5 – 20 KW
• Available in air and water cooled direct
expansion with refrigerant R-410A or chilled water systems
• Upflow and downflow configuration
• EC motor fans

Availability

  • Multi-functional Microprocessor Controller – Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.

Manageability

  • Heat Rejection Configurations – Available in air-cooled, water-cooled, and chilled water systems

LE SERIES

• Direct expansion air/water-cooled
• 20 – 100KW
• Refrigerant R-410A.
• Upflow and downflow configuration
• Backward-curved fan blades with EC motor

Availability

  • Active response control – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Direct drive motors – Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
  • Electronic expansion valve – Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
  • Multi-functional Microprocessor Controller – Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
  • Redundant Components – Single points of failure in the system have redundant components to maintain availability and reliability.

Energy management

  • Automatic Floor Pressurization System – Ensures stable airflow pressurization under floor regardless of changes made above the floor
  • Building Management Systems – Units are designed to work with the most common BMS systems including BACnet and Modbus.
  • Local area network – Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
  • Network interface – Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur

HIGH EFFICENCY

• Direct expansion air-cooled
• 15 – 150 KW
• Refrigerant R-410A.
• Upflow, downflow and underfloor fan module configurations
• Variable Speed Brushless Compressor

AM SERIES

• Direct expansion air/water-cooled
• Available in 2 cabinet sizes:
• 300mm, up to 12 KW (water)
• 600mm, up to 42 KW

Availability

  • Active response controls – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Predictable cooling – Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack Inlet Temperature Control – Reduces the risk of hot spots at the rack level

Manageability

  • Building management system integration – Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller – Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time Capacity Monitoring – Real-time display of current and available cooling.

Agility

  • Modular design – Modular design provides scalable solutions to add cooling as demand increases.
  • Scaleable densities – Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Total Cost of Ownership

  • In-Row architecture – Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans – Variable speed fans reduce energy consumption during off-peak cooling periods.

Serviceability

  • Easy service access – Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

LE SERIES

• Chilled Water
• Available in 2 cabinet sizes:
• 300mm, up to 40 KW with
standard operation
• 300mm, up to 60 KW with
high temperatures
• 600mm, up to 70 K

Availability

  • Active response controls – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Predictable cooling – Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack Inlet Temperature Control – Reduces the risk of hot spots at the rack level

Manageability

  • Building management system integration – Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller – Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time Capacity Monitoring – Real-time display of current and available cooling.

Agility

  • Modular design – Modular design provides scalable solutions to add cooling as demand increases.
  • Scaleable densities – Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Total Cost of Ownership

  • In-Row architecture – Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans – Variable speed fans reduce energy consumption during off-peak cooling periods.

Serviceability

  • Easy service access – Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

HIGH EFFICENCY

• 50 –1200 KW
• Free-cooling is an efficient
method to reduce energy
consumption at low outside
air temperatures. It
enhances energy optimization
in data center and process cooling.

Availability

  • Active response controls – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Predictable cooling – Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack Inlet Temperature Control – Reduces the risk of hot spots at the rack level

Manageability

  • Building management system integration – Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller – Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time Capacity Monitoring – Real-time display of current and available cooling.

Agility

  • Modular design – Modular design provides scalable solutions to add cooling as demand increases.
  • Scaleable densities – Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Total Cost of Ownership

  • In-Row architecture – Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans – Variable speed fans reduce energy consumption during off-peak cooling periods.

Serviceability

  • Easy service access – Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Speak with an Expert

To find the right product or service for you, contact us today to speak to one of our experts